Ready the day the auditor arrives.

Every calibration WLTR evaluates is captured, attributed and approved, with a complete trail from instrument export to final result. When the auditor asks how a calibration was accepted, the record answers.

The problem

An audit should not be an excavation.

In most labs, the evidence behind a calibration decision is assembled after the request arrives, from spreadsheets, exports and memory. Every reconstructed answer invites the next question.

01

Reconstructed history

The story of a batch is rebuilt days or years later, from whatever files and recollections survive.

02

Unanswerable questions

Who chose the model, what was excluded, and why. Without attribution, there is no good answer.

03

Findings that spread

One calibration finding invites a deeper look at every result built on top of it.

With WLTR

What the auditor sees

Original records kept

The first capture of the data is preserved and cannot be silently altered.

Attributable actions

Every evaluation, exclusion and approval is recorded against a named person.

A complete trail

From raw instrument export to approved result, every step is in the record.

Owned exclusions

A standard leaves the curve with a recorded reason and a name, never quietly.

Named QA approval

Sign-off is explicit, and the reviewer sees the same evidence the analyst did.

Language auditors recognize

Output aligns with ISO/IEC 17025, NELAP/TNI, GLP and GMP expectations.

Step 01 · Review

Watch the record build as the analyst works.

A fictional LC-MS/MS batch, reviewed the way an analyst would. Select a compound to see its curve, chromatograms and standards. Approve it, exclude a failing standard with a reason, or send it to QA, and the audit trail records each decision as it happens.

Try it yourself

See what a passing r² can hide in your own calibration.

Enter a curve, or load a sample, and see which levels actually back-calculate inside your acceptance window. Then work through a simulated LC-MS/MS quantitation review, laid out the way your data system shows it.

Simulation

This tool does not run WLTR’s engine, patented methodology or evaluation criteria. It applies eight standard least-squares calibration models and textbook acceptance rules. The batch and chromatograms are fictional. Everything is calculated in your browser, and nothing you enter is sent or stored.

Data
Calibration levels
#ConcentrationResponseRemove

Response can be a peak area or an area ratio to the internal standard. You can paste two columns straight from a spreadsheet into any cell.

r²
–
Levels in window
–

Calibration curve
Back-calculated accuracy by level

Each bar is a level’s error after back-calculation. The shaded band is your acceptance window.

Standard models compared (select a row)
Modelrr²Adj. r²Levels in windowWorst errorStatus

Simulation for illustration only. Sample datasets, the batch, chromatograms and names are fictional. Results on this page are not WLTR output, are not a method validation, and should not be used to accept or reject laboratory data.

Next · QA signs the record

Step 02 · Sign off

Every step, attributed and signed.

From upload to QA approval, every action is recorded against a named user with a time and a reason. This is the trail an auditor asks for, assembled before they ask.

Run 0412 · Calibration record · Illustrative
Pending QA review
  1. 09:14:02A. PatelAnalystUploaded ICAL_COMPOUND-A_RUN0412.TXT. SHA-256 recorded.
  2. 09:14:03WLTRSystemReadiness checks passed. Method configuration locked.
  3. 09:14:41WLTRSystemEvery candidate model scored against the acceptance criteria. Linear, 1/x² recommended.
  4. 09:22:15A. PatelAnalystSelected Linear, 1/x². No standards excluded. Submitted for QA review.
  5. 09:22:16WLTRSystemQA Director notified. Awaiting review and signature.
QA Director sign-offR. Okafor · QA Director

Signature meaning: Approval. I have reviewed this calibration record, its exceptions and its full audit trail, and I approve it for use.

Illustrative. In WLTR, approval requires the reviewer’s own credentials, and the signature is permanently linked to this record.

Next · Filed in the Audit Library

Step 03 · Store

Filed in the Audit Library.

Signed records do not go to a shared drive. They are filed in the Audit Library, locked, versioned and searchable, with the evidence attached. When the auditor asks, you search, open and export.

Illustrative wireframes · fictional names and data

01 · The library

Every signed record, one search away.

When QA signs, the record is locked and filed with everything behind the decision. Search by batch, method, instrument, compound or person, and filter to exactly what the auditor asked for.

  • Locked at signature, never edited in place
  • A correction becomes a new version; the original is kept
  • Every record carries its SHA-256 fingerprint
Illustrative wireframe · Audit Library

02 · The record

Open a record and the answer is already there.

Each compound’s model and decision, every exclusion with its reason and the name behind it, the full audit trail and both signatures, on one screen. The fingerprint is checked against the value recorded at signature.

  • Decisions and reasons for every compound
  • Audit trail from upload to signature
  • Signatures with name, time and meaning
Illustrative wireframe · Signed record

03 · The audit packet

Hand the auditor one packet.

Scope the export to the request, by study, method, instrument and date. WLTR assembles one packet: reports, original exports, configurations, evaluations, exclusions, audit trails, signatures and a manifest that verifies every file.

  • Scoped to the request, not the whole archive
  • Original files with a verification manifest
  • Assembled from the record, never rebuilt by hand
Illustrative wireframe · Audit packet export

One verification layer

Four solutions. One layer.

Each solution is one view of the same verification layer. Together they turn raw instrument output into a verified, traceable, QA-approved calibration record.

See your calibrations the way an auditor will.

We find operational inefficiencies & design the systems that eliminate it.