Solutions · Calibration Intelligence

Every candidate model. One screen.

WLTR ingests your calibration data, computes every candidate model, and scores each one in the Calibration Intelligence dashboard. The system runs the diagnostics and identifies the best fit. Your analyst makes the final decision.

The problem

Your data system fits one curve. It does not check its own work.

Instrument software fits a calibration curve with no independent check on its own output. Review happens one analyte at a time, on a screen built for something else.

01

One curve, taken on faith

The software fits a model and reports a correlation coefficient. Nothing independent ever questions it.

02

One analyte at a time

Curves are reviewed by hand on a small CDS window, compound by compound, batch after batch.

03

A strong r² can hide a failure

Correlation says little about accuracy at the low end, where reporting limits live.

With WLTR

What the dashboard shows

Every model computed

Standard regression models are computed for every analyte, not just the one the instrument picked.

Scored side by side

Each candidate model is evaluated against 15 acceptance criteria, so comparison is immediate and objective.

Best fit identified

Diagnostics run automatically and the strongest curve is flagged, with the reasoning attached.

The low end checked

Back-calculated accuracy is checked at every level, so a weak LLOQ cannot hide behind a strong r².

Exceptions surfaced

Passing curves move on. Review time goes to the calibrations that actually need a human.

Analyst in command

The system identifies the best fit. Your analyst sees the evidence and makes the final call.

See it work

Every candidate model, compared on one curve.

Load a sample curve or paste your own levels. Eight standard regression models are fitted side by side with r², worst %RE and a level-by-level back-calculation, so the best fit is visible instead of assumed.

Try it yourself

See what a passing r² can hide in your own calibration.

Enter a curve, or load a sample, and see which levels actually back-calculate inside your acceptance window. Then work through a simulated LC-MS/MS quantitation review, laid out the way your data system shows it.

Simulation

This tool does not run WLTR’s engine, patented methodology or evaluation criteria. It applies eight standard least-squares calibration models and textbook acceptance rules. The batch and chromatograms are fictional. Everything is calculated in your browser, and nothing you enter is sent or stored.

Data
Calibration levels
#ConcentrationResponseRemove

Response can be a peak area or an area ratio to the internal standard. You can paste two columns straight from a spreadsheet into any cell.

r²
–
Levels in window
–

Calibration curve
Back-calculated accuracy by level

Each bar is a level’s error after back-calculation. The shaded band is your acceptance window.

Standard models compared (select a row)
Modelrr²Adj. r²Levels in windowWorst errorStatus

Simulation for illustration only. Sample datasets, the batch, chromatograms and names are fictional. Results on this page are not WLTR output, are not a method validation, and should not be used to accept or reject laboratory data.

One verification layer

Four solutions. One layer.

Each solution is one view of the same verification layer. Together they turn raw instrument output into a verified, traceable, QA-approved calibration record.

See what WLTR finds in your data.