Supported systems
Works with the instruments and data systems you already run.
Agilent, Waters, Shimadzu, Thermo Fisher Scientific, SCIEX, Bruker, PerkinElmer, Hamilton. WLTR reads the calibration exports your chromatography data system already produces. No new hardware, no instrument drivers, and no change to how your instruments acquire or process data.
Contract research and bioanalytical labs
Built for the LC-MS/MS work CROs run every day.
Bioanalytical and contract research labs run regulated assays for many sponsors at once, often on instruments from more than one manufacturer. WLTR applies one objective evaluation to every calibration, whichever system produced it.
Built for LC-MS/MS assays
WLTR evaluates the calibration curves behind GLP and clinical sample analysis on the triple quadrupole systems CROs rely on, from SCIEX, Waters, Thermo Fisher Scientific and Agilent.
Every level checked, including the LLOQ
Back-calculated accuracy is checked at every calibration level against the limits your validated method sets, so a strong r² cannot hide a failing LLOQ.
One record for every sponsor
Exports from different instruments and data systems are evaluated the same way, so every sponsor receives the same consistent, documented calibration record.
Audit-ready from the first run
Each evaluation is hashed, documented and routed through QA approval, ready for sponsor audits and regulatory inspections.
By manufacturer
The instruments behind regulated results.
Common GC, GC-MS, headspace, HPLC, LC-MS/MS and ion chromatography systems in contract research and bioanalytical, pharma, environmental, cannabis, food and forensic labs, and the data systems that run them.
Data systems: OpenLab CDS · MassHunter
-
Gas chromatograph
Agilent 8890 GC
VOCs, petroleum hydrocarbons, pesticides
-
GC-MS
Agilent 5977C GC/MSD
EPA 8260 and 8270 volatiles and semivolatiles
-
GC-MS/MS
Agilent 7000E GC/TQ
Multi-residue pesticides
-
Headspace GC
Agilent 8697 Headspace Sampler
Residual solvents, blood alcohol
-
UHPLC
Agilent 1290 Infinity III LC
Cannabinoid potency, assay methods
-
LC-MS/MS
Agilent 6495D LC/TQ
PFAS, drug confirmation, bioanalysis
Data systems: Empower · MassLynx and TargetLynx · waters_connect
-
HPLC
Waters Alliance iS HPLC
Potency and assay methods
-
UHPLC
Waters ACQUITY Premier UPLC
Bioanalytical and residue methods
-
LC-MS/MS
Waters Xevo TQ Absolute
Bioanalysis, PFAS
-
LC-MS/MS
Waters Xevo TQ-S micro
Drug confirmation, mycotoxins
Data systems: LabSolutions
-
Gas chromatograph
Shimadzu Nexis GC-2030
Petroleum hydrocarbons, solvents
-
GC-MS
Shimadzu GCMS-QP2020 NX
Volatiles and semivolatiles
-
GC-MS/MS
Shimadzu GCMS-TQ8050 NX
Multi-residue pesticides
-
Headspace GC
Shimadzu HS-20 NX
Residual solvents, blood alcohol
-
UHPLC
Shimadzu Nexera series
Cannabinoid potency, assay methods
-
LC-MS/MS
Shimadzu LCMS-8060NX
PFAS, bioanalysis, mycotoxins
Data systems: Chromeleon CDS · TraceFinder
-
Gas chromatograph
Thermo TRACE 1610 GC
Petroleum hydrocarbons, solvents
-
GC-MS
Thermo ISQ 7610
Volatiles and semivolatiles
-
GC-MS/MS
Thermo TSQ 9610
Multi-residue pesticides
-
UHPLC
Thermo Vanquish UHPLC
Potency and assay methods
-
LC-MS/MS
Thermo TSQ Altis Plus
PFAS, bioanalysis, drug confirmation
-
Ion chromatography
Thermo Dionex Inuvion IC
Anions and inorganic analytes
Data systems: SCIEX OS · Analyst
-
LC-MS/MS
SCIEX 7500 system
PFAS, forensic toxicology, bioanalysis
-
LC-MS/MS
SCIEX QTRAP 6500+
Bioanalysis, drug confirmation
-
LC-MS/MS
SCIEX Triple Quad 5500+
Residues, mycotoxins, drugs of abuse
Data systems: TASQ · Compass
-
LC-MS/MS
Bruker EVOQ LC-TQ
Pesticides, mycotoxins, targeted quantitation
-
DART-MS/MS
Bruker EVOQ DART-TQ+
Chromatography-free screening, food and cannabis
-
LC-TIMS-MS/MS
Bruker timsTOF
Bioanalysis, metabolomics, biomarker quantitation
Data systems: TotalChrom · Simplicity Chrom
-
Gas chromatograph
PerkinElmer GC 2400
Petroleum hydrocarbons, solvents, pesticides
-
Gas chromatograph
PerkinElmer Clarus 690 GC
VOCs, semivolatiles, environmental methods
-
GC-MS
PerkinElmer Clarus SQ 8
Volatiles and semivolatiles
-
Headspace GC
PerkinElmer TurboMatrix HS
Residual solvents, blood alcohol, VOCs
-
HPLC
PerkinElmer LC 300
Potency, assay and purity methods
-
LC-MS/MS
PerkinElmer QSight 420
Pesticides, mycotoxins, PFAS, cannabinoids
Data systems: VENUS
-
Liquid handler
Hamilton Microlab STAR
Calibration standard and dilution series preparation
-
Liquid handler
Hamilton Microlab NIMBUS
Sample preparation for LC-MS/MS and GC-MS batches
-
Liquid handler
Hamilton Microlab Prep
Standard preparation in smaller labs
-
Liquid handler
Hamilton Microlab VANTAGE
High-throughput bioanalytical sample preparation
Manufacturer names and logos, instrument names and software names are trademarks of their respective owners and are used only to identify compatible systems. WLTR is independent and is not affiliated with or endorsed by these manufacturers. Compatibility depends on your export configuration; send us a sample export to confirm.
How data gets in
From export to evaluation in three steps.
-
Export
Export the calibration run from your chromatography data system as a text file, the same way you would for review or archiving.
-
Upload
Upload the file to WLTR. It is parsed, hashed with SHA-256 and kept as the original record, and analytes are mapped to consistent names.
-
Evaluate and return
WLTR evaluates the calibration against 15 acceptance criteria and returns an approved record your team can file with the batch and reference in your LIMS or ELN.
Where WLTR fits
A verification layer, not a replacement.
Stays in place
Your chromatography data system keeps acquiring, processing and storing your data. WLTR verifies the calibration it produced.
Verified records flow in
WLTR sits between the instrument and your LIMS or ELN, so verified calibration records reach the systems your lab already trusts.
Configured, not replaced
Acceptance criteria, roles and approval gates are configured to your methods.
One standard across vendors
Labs running instruments from several manufacturers get one consistent calibration evaluation across all of them.
Questions
Frequently asked questions
Which data systems does WLTR work with?
WLTR works from the text exports produced by the major chromatography data systems, including Agilent OpenLab CDS and MassHunter, Waters Empower and MassLynx, Shimadzu LabSolutions, Thermo Fisher Chromeleon and TraceFinder, SCIEX OS and Analyst, and PerkinElmer TotalChrom and Simplicity Chrom. Send us a sample export from your system to confirm your configuration.
Our instrument is not listed. Will WLTR work?
Most likely. WLTR reads exported calibration data rather than connecting to the instrument, so the model matters less than the export. Email a representative export to admin@wltr.tech and we will confirm.
Do we need to install anything on our instruments?
No. WLTR works from exported files. Nothing is installed on your instruments or your data system.
Can WLTR handle long target lists?
Yes. WLTR maps every analyte to a consistent name so methods with dozens or hundreds of analytes can be evaluated and trended across runs and instruments.
Next step
Check your data system in one demo.
Bring a representative instrument export. We will show the full path from your file to an approved calibration record.