Missouri DNR and DHSS
Missouri environmental lab certification, DNR and drinking water.
Which Missouri agencies certify and audit drinking water labs, how out-of-state labs qualify, what the wastewater rule requires instead, and where calibration requirements come from.
At a glance
How environmental lab certification works in Missouri.
Missouri is not a NELAP state. Its certification program covers labs that analyze samples for the Department of Natural Resources’ Public Drinking Water Branch, under the drinking water rules in 10 CSR 60-5.
Drinking water lab certification
- Drinking water program
- Missouri Department of Natural Resources certifies labs for drinking water analyses. Chemical labs work with the department’s Environmental Services Program.
- Microbiology
- Staff of the State Public Health Laboratory, Missouri Department of Health and Senior Services, serve as Laboratory Certification Officers and perform on-site evaluations for DNR’s program.
- Rule
- 10 CSR 60-5.010 (acceptable procedures for analysis) and 10 CSR 60-5.020 (laboratory certification), last amended effective December 30, 2021
- Who needs it
- Any lab doing testing required by DNR’s Public Drinking Water Branch. Analysis of samples from private residences or private wells does not have to be done by a certified lab.
- Wastewater
- 10 CSR 20-7.015 requires analytical and sampling methods that conform to 40 CFR 136.3, as published August 28, 2017. The rule text does not require analysis by a certified laboratory.
- Out-of-state labs
- Certification by reciprocity requires a copy of the successful audit from the certifying authority and the current certificate (10 CSR 60-5.020(1)(B)). DNR will also consider out-of-state results on written request (10 CSR 60-5.020(17)).
- NELAP status
- Not a NELAP accreditation body, as of October 2026. Missouri does not appear on TNI’s list of NELAP accreditation bodies.
The accreditation cycle
The Missouri certification cycle.
The steps below summarize 10 CSR 60-5.020 and the Department of Health and Senior Services certification page. Your certificate and DNR correspondence govern the specifics for your lab.
-
Apply to the right agency
Chemical labs contact DNR’s Environmental Services Program. Microbiological labs follow the Department of Health and Senior Services certification process for DNR’s program.
-
Pass an audit
A lab applying directly must pass a certification audit conducted by DNR or the Department of Health and Senior Services. For microbiology, renewal is based on triennial on-site evaluations.
-
Proficiency testing
Performance evaluation samples at least once per year for each analyte and by each method used to analyze compliance samples.
-
Three-year certificate
Certification is issued for three years (10 CSR 60-5.020(1)(C)). Major personnel changes, such as losing or replacing the laboratory supervisor, must be reported within 30 days.
Initial calibration
What auditors check in your initial calibrations.
Missouri’s certification rule does not set calibration criteria of its own. It requires drinking water analyses to follow the federally approved methods, so the calibration expectations come from those methods.
A range that brackets what you report
The lowest standard should sit at or below your reporting limit and the highest at or above the top concentration you report. Results outside the calibrated range need to be qualified.
Error at the low end, not r² alone
A correlation coefficient of 0.999 can still hide a low standard that back-calculates 30 percent off. Auditors look at relative error, especially at the lowest levels.
Records that rebuild the curve
Raw responses, the model and weighting used, any excluded points with the reason, and the verification that followed. An auditor should be able to reconstruct every initial calibration from the record.
The approved method sets the calibration
10 CSR 60-5.010 requires drinking water analyses to use the methods in 40 CFR 141 and 143, as of the July 1, 2021 Code of Federal Regulations, unless a substitute is approved. Neither 10 CSR 60-5 rule sets calibration criteria, so each method’s calibration requirements apply.
Source: 10 CSR 60-5.010; 40 CFR 141 and 143
For microbiology, the Department of Health and Senior Services lists its certification requirements as those in the US EPA Manual for the Certification of Laboratories Analyzing Drinking Water, 5th Edition, 2005, Chapter 5.
Self-check
Are your initial calibrations ready for a Missouri assessment?
Tick what your lab could show an auditor today. Nothing you select is saved or sent anywhere.
6Checks to work through
Select each item your lab could show an auditor today.
A self-assessment to help you prepare, not a compliance determination.
Missouri specifics
Missouri’s lab certification rule covers drinking water testing.
Missouri’s lab certification rule sits in the drinking water regulations, 10 CSR 60-5. A certified lab must be used for any testing required by DNR’s Public Drinking Water Branch. DNR certifies the lab, and the audit can be performed by DNR or by the Department of Health and Senior Services, whose State Public Health Laboratory staff serve as Laboratory Certification Officers for microbiology.
Wastewater is handled differently. The effluent rule, 10 CSR 20-7.015, requires analytical and sampling methods that conform to 40 CFR 136.3, incorporated as published August 28, 2017, but its text does not require a certified laboratory. For a wastewater lab, the approved method sets the calibration requirements your records should meet.
As of October 2026, the current text of 10 CSR 60-5 shows its last amendment filed April 29, 2021 and effective December 30, 2021, incorporating the July 1, 2021 Code of Federal Regulations by reference. We found no 2025 or 2026 amendment to the certification rule.
How WLTR helps
Calibration evidence ready for a Missouri audit.
WLTR independently reviews the calibration your instrument software produced. Your analyst still makes the final call. What changes is that the evidence is complete, consistent across analysts, and ready before the auditor asks for it.
- Each analyte reviewed one at a time in the instrument software.
- The model and weighting are whatever the batch was processed with.
- r² is the number most people look at, even though it does not measure error at the low end.
- QA signs off without an independent check on the curve.
- Every analyte and every candidate model side by side in the Calibration Intelligence dashboard.
- Diagnostics run automatically and the best fit curve is identified, with the reasons recorded.
- Relative error at every level, including the lowest standard, shown on one screen.
- A traceable record your QA manager can review, sign and hand to a state auditor.
See how your own ICAL data looks when every analyte and model is laid out for review.
Questions
Missouri accreditation FAQs
Is Missouri a NELAP state?
No. As of October 2026, Missouri does not appear on TNI’s list of NELAP accreditation bodies. The Department of Natural Resources certifies drinking water labs under its own rule, 10 CSR 60-5.020.
Who certifies drinking water labs in Missouri?
The Missouri Department of Natural Resources. Chemical labs work with DNR’s Environmental Services Program, and for microbiology, State Public Health Laboratory staff at the Department of Health and Senior Services perform on-site evaluations for DNR’s program.
Does Missouri certify wastewater labs?
The effluent rule, 10 CSR 20-7.015, requires methods that conform to 40 CFR 136.3, but its text does not require analysis by a certified laboratory. DNR’s certification pages cover drinking water testing.
Can an out-of-state lab be certified in Missouri?
Yes. A lab seeking certification by reciprocity submits a copy of the successful audit from its certifying authority and its current certificate, and must still demonstrate proficiency (10 CSR 60-5.020(1)(B)). DNR will also consider out-of-state results on written request.
How long does Missouri certification last?
Three years (10 CSR 60-5.020(1)(C)). Labs analyze performance evaluation samples at least once per year for each analyte and method, and microbiology renewal is based on triennial on-site evaluations.
Sources
Primary sources for this page.
- TNI, NELAP accreditation bodies (opens in a new tab)
- Missouri DNR, certified laboratories (opens in a new tab)
- Missouri DNR, certified chemical laboratories (opens in a new tab)
- Missouri DHSS, State Public Health Laboratory certifications (opens in a new tab)
- 10 CSR 60-5, Missouri Code of State Regulations (Secretary of State) (opens in a new tab)
- 10 CSR 60-5.020, laboratory certification (Cornell LII copy) (opens in a new tab)
- 10 CSR 60-5.010, procedures for analysis (Cornell LII copy) (opens in a new tab)
- 10 CSR 20-7.015, effluent regulations (Cornell LII copy) (opens in a new tab)
This page summarizes public program information to help labs prepare. Requirements change, and the agency’s current rules and guidance always take precedence. WLTR is not affiliated with or endorsed by the Missouri Department of Natural Resources. Spot something out of date? Tell us at admin@wltr.tech.
Before your next assessment
See your Missouri ICALs the way an auditor will.
Bring a recent initial calibration. We will walk you through every analyte and candidate model in the Calibration Intelligence dashboard, the best fit, and the record your QA manager would sign.
Request a demoHow the methodology works
Running environmental methods? See how WLTR works for environmental testing labs and water and wastewater utility labs.