Hawaii DOH State Laboratories Division

Hawaii drinking water lab certification, the State Laboratories Division.

Which Hawaii agency certifies your lab, what the drinking water program requires, how out-of-state labs are approved, and what auditors look for in your initial calibrations.

Request a demoWhat auditors check

ProgramDrinking water only
AgencyDOH State Laboratories Division
StandardEPA DW certification manual, 5th ed.
RuleHAR 11-20-15

At a glance

How drinking water lab certification works in Hawaii.

Hawaii is not a NELAP state. The Department of Health’s State Laboratories Division certifies labs that test drinking water compliance samples from Hawaii, following the EPA drinking water certification manual.

Drinking water lab certification

Program
Drinking Water Laboratory Certification Program, Environmental Health Analytical Services Branch, State Laboratories Division, Hawaii State Department of Health. The division states it is approved by EPA to administer the program.
Legal basis
HAR 11-20-15 counts drinking water compliance samples only if they were analyzed by a laboratory certified by the director, as specified in EPA’s Manual for the Certification of Laboratories Analyzing Drinking Water, 5th edition, January 2005.
Who needs it
Labs analyzing samples used to determine compliance with the sections of the public water system rules (HAR chapter 11-20) that HAR 11-20-15 lists. HAR 11-20-15 lets any person acceptable to the director measure turbidity, disinfectant residual, temperature, alkalinity, calcium, conductivity, orthophosphate, silica and pH.
Scope
The State of Hawaii states it only certifies laboratories that test drinking water compliance samples from Hawaii. Labs are certified by analyte or test, and certification is in effect for one year.
Other water analyses
HAR 11-54-10 requires water quality compliance analyses to be performed by a laboratory approved by the department and cites 40 CFR 136 among the methods. The rule sets out no approval procedure, and the department publishes no separate wastewater lab certification program.
Out-of-state labs
Approved for chemistry regulatory monitoring only, based on home-state drinking water certification or NELAP certification. Out-of-state approval for regulatory microbiological testing is not offered, and Hawaii has no formal reciprocity agreements.
NELAP status
Not a NELAP accreditation body (TNI list, as of October 2026). The program accepts NELAP certification when approving out-of-state labs.

The accreditation cycle

The drinking water certification cycle.

The steps below summarize the State Laboratories Division’s requirements for in-state drinking water labs. Your certificate and correspondence from the certification officers govern the specifics for your lab.

  1. Certify by analyte or test

    Apply for each analyte or test you report, using the methods specified by the drinking water regulations, with a written Quality Assurance Plan that includes your SOPs.

  2. Proficiency testing

    Successfully complete an annual Water Supply Proficiency Testing (WS-PT) study for each analyte, and submit the initial demonstration of capability for each method to the State at least once per year.

  3. On-site audit

    Pass a biennial on-site audit by the State of Hawaii drinking water certification officers.

  4. Annual certification

    Drinking water certification is in effect for one year.

Initial calibration

What auditors check in your initial calibrations.

Hawaii has no separate calibration rule. The calibration requirements come from the EPA drinking water certification manual the rule adopts and from the EPA methods under 40 CFR 141 for which your lab is certified.

01

A range that brackets what you report

The lowest standard should sit at or below your reporting limit and the highest at or above the top concentration you report. Results outside the calibrated range need to be qualified.

02

Error at the low end, not r² alone

A correlation coefficient of 0.999 can still hide a low standard that back-calculates 30 percent off. Auditors look at relative error, especially at the lowest levels.

03

Records that rebuild the curve

Raw responses, the model and weighting used, any excluded points with the reason, and the verification that followed. An auditor should be able to reconstruct every initial calibration from the record.

04

Methods and a QA plan the certification officers can audit

HAR 11-20-15 certifies labs as specified in EPA’s drinking water certification manual, and the State Laboratories Division requires the methods specified by the drinking water regulations and a written Quality Assurance Plan with SOPs. Your calibration practice has to match both.

Source: HAR 11-20-15; Hawaii DOH in-state drinking water certification requirements

Out-of-state labs are approved for chemistry only, and the State Laboratories Division expects them to keep submitting new on-site audit and CAR reports from their home program.

Self-check

Are your initial calibrations ready for a Hawaii assessment?

Tick what your lab could show an auditor today. Nothing you select is saved or sent anywhere.

6Checks to work through

Select each item your lab could show an auditor today.

Request a demo

A self-assessment to help you prepare, not a compliance determination.

Hawaii specifics

A drinking water program, with chemistry only for out-of-state labs.

Hawaii’s certification program is built around drinking water. The State Laboratories Division states that it only certifies laboratories that test drinking water compliance samples from Hawaii, and it certifies them by analyte or test in accordance with the EPA drinking water certification manual.

Out-of-state labs face a narrower path. Hawaii has no formal reciprocity agreements, but it approves chemistry regulatory monitoring data from labs with home-state drinking water certification or NELAP certification. Out-of-state approval for regulatory microbiological testing is not offered, and at least one acceptable WS-PT result per analyte is required each year.

The State Laboratories Division’s in-state drinking water requirements document is marked Rev. 2026, so check the current version before an audit. For other water quality analyses, HAR 11-54-10 requires a laboratory approved by the department and cites 40 CFR 136 among its methods, but it sets out no approval procedure, so confirm expectations with the permitting branch.

How WLTR helps

Calibration evidence ready for a Hawaii drinking water audit.

WLTR independently reviews the calibration your instrument software produced. Your analyst still makes the final call. What changes is that the evidence is complete, consistent across analysts, and ready before the auditor asks for it.

Calibration review today

  • Each analyte reviewed one at a time in the instrument software.
  • The model and weighting are whatever the batch was processed with.
  • r² is the number most people look at, even though it does not measure error at the low end.
  • QA signs off without an independent check on the curve.
With WLTR

  • Every analyte and every candidate model side by side in the Calibration Intelligence dashboard.
  • Diagnostics run automatically and the best fit curve is identified, with the reasons recorded.
  • Relative error at every level, including the lowest standard, shown on one screen.
  • A traceable record your QA manager can review, sign and hand to a Hawaii drinking water certification officer.

See how your own ICAL data looks when every analyte and model is laid out for review.

Request a demo

Questions

Hawaii accreditation FAQs

Is Hawaii a NELAP state?

No. Hawaii is not on TNI’s list of NELAP accreditation bodies as of October 2026. The State Laboratories Division does accept NELAP certification when it approves out-of-state labs for chemistry.

Who certifies drinking water labs in Hawaii?

The Drinking Water Laboratory Certification Program in the State Laboratories Division, Hawaii State Department of Health, under HAR 11-20-15 and the EPA Manual for the Certification of Laboratories Analyzing Drinking Water, 5th edition.

Can an out-of-state lab report Hawaii drinking water data?

For chemistry, yes, with home-state drinking water certification or NELAP certification and at least one acceptable WS-PT result per analyte each year. Out-of-state approval for regulatory microbiological testing is not offered, and Hawaii has no formal reciprocity agreements.

How long does certification last?

Drinking water certification is in effect for one year. In-state labs must also complete an annual WS-PT study and pass a biennial on-site audit by the State’s certification officers.

Does Hawaii have its own initial calibration rule?

No separate rule. HAR 11-20-15 adopts the EPA drinking water certification manual, so calibration requirements come from that manual and from the EPA methods under 40 CFR 141 for which your lab is certified.

Sources

Primary sources for this page.

Before your next assessment

See your Hawaii ICALs the way a certification officer will.

Bring a recent initial calibration. We will walk you through every analyte and candidate model in the Calibration Intelligence dashboard, the best fit, and the record your QA manager would sign.

Request a demoHow the methodology works

Running environmental methods? See how WLTR works for environmental testing labs and water and wastewater utility labs.